Laurel-electronics LAUREATE SERIES 2 DIGITAL PANEL METER Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Laurel-electronics LAUREATE SERIES 2 DIGITAL PANEL METER herunter. Laurel Electronics LAUREATE SERIES 2 DIGITAL PANEL METER User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 2 - 1. ORDERING GUIDE

10 8. FRONT PANEL SETUP KEYS Meter Front Panel There are four front panel keys, which change function for the Run Mode and Menu Mode, effectively

Seite 3 - 2. TABLE OF CONTENTS

11 KEYS IN MENU MODE Right Arrow Key (MENU). Pressing steps the meter through all menu items that have been enabled and then back to the

Seite 4 - 3. PRODUCT INTRODUCTION

12 9. ENABLING & LOCKING OUT MENU ITEMS For security reasons and ease of meter operation, any and all menu items may be disabled or &

Seite 5 - 5. SAFETY CONSIDERATIONS

13 10. READING COORDINATES OF 2 POINTS SCALING METHOD When the reading coordinates of 2 points scaling method has been selected under SEtuP, the f

Seite 6

14 11. DC VOLTS, AMPS, PROCESS, STRAIN INPUT The DC Volts, Amps, Process and Strain meters utilize the DC signal conditioner board, which needs to

Seite 7 - RS485 INTERFACE - HALF DUPLEX

15 Board Revisions Q and R 1. Letters indicate jumper position. Jumpers are installed on pins adjacent to letters. 2. Use 5 mm (0.2") jumpers

Seite 8 - 7. MECHANICAL ASSEMBLY

16 KEYSTROKES FOR SETUP If the MENU key does not work, see Section 9 “Enabling & Locking Out Menu Items.” Press Menu Select Key Pr

Seite 9

17 Press Menu Select Key Press Digit Select Key Press Value Select Key 000_0 Operation as a rate of change meter. Extended meter only. 0

Seite 10 - 8. FRONT PANEL SETUP KEYS

18 Press Menu Select Key Press Digit Select Key Press Value Select Key Scaling method “Scale and Offset” if selected under SEtuP SCALE

Seite 11

19 Option board dependent menu items ALSEt. ALS34 dEU1H dEU2H dEU1b dEU2b dEU3H DEU4H DEU3b DEU4b Menu items related to alarm setup These w

Seite 12 - Menu Items

2 1. ORDERING GUIDE Configure a model number in this format: L20201DCV1, CBL01 L…….Digital panel meter with screw terminal connectors. Display

Seite 13

20 12. LOAD CELL & MICROVOLT INPUT Notes 1. See Section 19 to select 10V excitation. 2. Jumpers are 2.5 mm (0.1 in). SCALE &

Seite 14

21 KEYSTROKES FOR SETUP If the MENU key does not work, see Section 9 “Enabling & Locking Out Menu Items.” Press Menu Select Key Press

Seite 15

22 Press Menu Select Key Press Digit Select Key Press Value Select Key 000_0 Operation as a rate of change meter. Extended meter only.

Seite 16

23 Press Menu Select Key Press Digit Select Key Press Value Select Key Scaling method “Scale and Offset” if selected under SEtuP SCALE S

Seite 17

24 Option board dependent menu items ALSEt. ALS34 dEU1H dEU2H dEU1b dEU2b dEU3H DEU4H DEU3b DEU4b Menu items related to alarm setup These w

Seite 18

25 13. AC TRUE RMS VOLTS & AMPS INPUT AC voltage or current measurement utilizes the True RMS signal conditioner board which uses prec

Seite 19

26 can be set for direct readout in (milli)volts or (milli)amperes. Decimal point selection does not affect the counts. For example, a 20V input may

Seite 20

27 KEYSTROKES FOR SETUP If the MENU key does not work, see Section 9 “Enabling & Locking Out Menu Items.” Press Menu Select Key P

Seite 21

28 Press Menu Select Key Press Digit Select Key Press Value Select Key 000_0 Operation as a rate of change meter. Extended meter only. 0

Seite 22

29 Press Menu Select Key Press Digit Select Key Press Value Select Key Scaling method “Scale and Offset” if selected under SEtuP SCALE S

Seite 23

3 2. TABLE OF CONTENTS 1. ORDERING GUIDE ...

Seite 24

30 Option board dependent menu items ALSEt. ALS34 dEU1H dEU2H dEU1b dEU2b dEU3H DEU4H DEU3b DEU4b Menu items related to alarm setup These w

Seite 25 - of 0. The decimal point

31 14. THERMOCOUPLE INPUT The thermocouple signal conditioner board used for temperature measurement can be confi-gured via jumpers for 7 thermocou

Seite 26

32 KEYSTROKES FOR SETUP If the MENU key does not work, see Section 9 “Enabling & Locking Out Menu Items.” Press Menu Select Key Pr

Seite 27

33 Press Menu Select Key Press Digit Select Key Press Value Select Key 000_0 0 No used. ConFG Meter Configuration 00 _ _0 Operation of

Seite 28

34 15. RTD & RESISTANCE INPUT The standard RTD and resistance signal conditioner board can be configured via jumpers for four RTD types (DIN

Seite 29

35 RTD & RESISTANCE CONNECTION With the appropriate jumper settings, RTD and resistance measurements allow 2, 3 or 4-wire RTD hookup to

Seite 30

36 KEYSTROKES FOR SETUP If the MENU key does not work, see Section 9 “Enabling & Locking Out Menu Items.” Press Menu Select Key P

Seite 31 - 14. THERMOCOUPLE INPUT

37 Press Menu Select Key Press Digit Select Key Press Value Select Key SEtuP Meter Setup (continued) 00_00 Control inputs 1 & 2 (co

Seite 32 - True = logic 1 (0V or

38 Press Menu Select Key Press Digit Select Key Press Value Select Key FiLtr Filtering (continued) 00000 Input signal filtering. Can be

Seite 33

39 16. DUAL OR QUAD RELAY OUTPUT OPTION An optional relay board may be installed in the meter main board at plug position P2, adjacent to

Seite 34

4 3. PRODUCT INTRODUCTION Our digital panel meters are versatile, cost effective solutions to a wide variety of monitoring and control application

Seite 35

40 KEYSTROKES FOR SETPOINT SETUP If the MENU key does not work, see Section 9 “Enabling & Locking Out Menu Items.” Press Menu Select Key

Seite 36

41 Press Menu Select Key Press Digit Select Key Press Value Select Key 00000 Alarm operates at and above setpoint (active high) or at

Seite 37 - (continued)

42 17. ANALOG OUTPUT OPTION An optional analog board may be installed in the meter at rear panel jack position J4, adjacent to the signal conditi

Seite 38

43 18. SERIAL COMMUNICATION OPTIONS A serial communications board may be connected to the meter main board at plug position P13 (middle position)

Seite 39

44 Basic Ethernet Board No jumpers needed. RS232 Board e - Normal operation. f - Slave display to RS232 from another meter. g - Pull-up re

Seite 40

45 SERIAL CONNECTION EXAMPLES

Seite 41

46 KEYSTROKES FOR SETUP If the MENU key does not work, see Section 9 “Enabling & Locking Out Menu Items.” Press Menu Select Key P

Seite 42 - 17. ANALOG OUTPUT OPTION

47 Press Menu Select Key Press Digit Select Key Press Value Select Key _0000U Line feed 0 No line feed after carriage return 1 Line feed

Seite 43

48 19. EXCITATION OUTPUT & POWER SUPPLY Three isolated transducer excitation output levels are available from the power supply board. These ar

Seite 44

49 20. INSTRUMENT SETUP VIA PC Instrument Setup software is a PC program which is much easier to learn than front panel programming. It is of

Seite 45 - SERIAL CONNECTION EXAMPLES

5 4. RECEIVING & UNPACKING Your meter was carefully tested and inspected prior to shipment. Should the meter be damaged in shipm

Seite 46

50 SETUP OF CONNECTED METER A setup file can be retrieved from the meter (DPM => Get Setup), be edited (View => Setup), be s

Seite 47

51 • The Readings pull-down menu provides three formats to display DPM data on the PC monitor. Use the Pause and Continue buttons to co

Seite 48

52 21. CUSTOM CURVE LINEARIZATION Curve.exe is a DOS-based, executable PC program used to set up an Extended meter so that the readings have a

Seite 49

53 4) Equation entry mode, where the coefficients of a polynomial Y = K1X^P1 + K2X^P2 + K3*X^P3 + … are entered. Up to 20 terms are allowed. An offs

Seite 50 - The Commands pull-down menu

54 22. METER CALIBRATION All analog input and analog output ranges of the meter have been digitally calibrated at the factory p

Seite 51

55 23. SPECIFICATIONS Meter Display Type ...5 LED, 7-segment, 14.2mm (.56") high digits & 3 LED indic

Seite 52

56 DC Volts Range Resol. Resist. Error 200.00 mV 2.0000 V 20.000 V 200.00 V 300.0 V 10 µV 100 µV 1 mV 10 mV 100 mV 1 GΩ 1 GΩ 10 MΩ 10 MΩ 10 MΩ 0.

Seite 53

57 Load Cell Input Range Resolution Resistance Zero Range Span Range Error 20.000 mV 50.000 mV 100.00 mV 250.00 mV 500.00 mV 1 µV 2.5 µV 5 µV 1

Seite 54 - 22. METER CALIBRATION

- 58 - Accuracy ...Meter input accuracy ±0.02% of full scale analog output Resolution ...

Seite 55 - 23. SPECIFICATIONS

- 59 - 24. GLOSSARY OF TERMS Adaptive Filter Threshold A threshold which causes an adaptive moving average filter to be reset to the latest readi

Seite 56

6 6. CONNECTOR WIRING INFORMATION CONNECTORS Connectors for signal and power are UL-rated screw-clamp terminal blocks that plug into mating jacks o

Seite 57

- 60 - Deviation limits are programmed by entering menu item dEU1b for Alarm 1 and dEU2b for Alarm 2. The deviation band equals two limits.

Seite 58 - Environmental

- 61 - Menu Mode The meter programming mode used for input and range selection, meter setup, and meter configuration. Entered into from the R

Seite 59 - 24. GLOSSARY OF TERMS

- 62 - Remote Display A display mode which allows the meter to serve as a remote display to another meter when connected to it by a 4-wire phone

Seite 60

- 63 - Scaling, Reading Coordinates of 2 Points Method A scaling method, where the low and high input values are determined from actual

Seite 61 - Peak Display

- 64 - 25. WARRANTY Laurel Electronics Inc. warrants its products against defects in materials or workmanship for a period of one year from the d

Seite 62

7 P3 - SERIAL COMMUNICATIONS P4 - ANALOG OUTPUT N/CISO GNDRXTXRTSN/CGNDTXRXRTSRS232 INTERFACE Computer654321ISO GNDBRXARXATXBTXISO GND

Seite 63

8 7. MECHANICAL ASSEMBLY REMOVING THE REAR PANEL First remove any connectors. Use one hand to press in the two sides of the rear of

Seite 64 - EXCLUSIVE REMEDIES

9 Note: Corresponding main board and option board connectors have the same number of electrical lines. When an option board is correctly