LAUREL Electronics Inc.3183-G Airway Ave, Costa Mesa, CA USA 92626Tel: (714) 434-6131 Fax: (714) 434-3766 Website: www.laurels.comLAUREATE SERIESDP

Seite 2 - ORDERING GUIDE

-8-8. FRONT PANEL SETUP KEYSFigure 8.1ALARM 2 STATUSINDICATORMENU KEYThe menu key steps through the various meter parameters that may be selected. Th

Seite 3 - CONTENTS

-9-9. SETTING MENU LOCKOUTSFor security and ease of operation, any or all program menu items may be disabled. Eachfunction to be disabled is set to

Seite 4 - 1. INTRODUCTION

-10-DIGIT SELECT KEY VALUE SELECT KEY MENU KEY Press to select "0" or "1"for flashing digit2 - Alarm Setup3 - Alarm setpoin

Seite 5 - 3. SAFETY CONSIDERATIONS

-11-TRUE RMS SIGNAL CONDITIONERVALUE SELECT KEY MENU KEY DIGIT SELECT KEY TEMPERATURE SIGNAL CONDITIONER InPutInput signal type J°F J°C K°F K

Seite 6

-12-DIGIT SELECT KEY VALUE SELECT KEY MENU KEY LOAD CELL SIGNAL CONDITIONER 20.0 50.0 100.0 250.0 500.020, 50, 100, 250, 500 mV

Seite 7 - 4.6 J3 DIGITAL INTERFACE

-13-DIGIT SELECT KEY VALUE SELECT KEY MENU KEY 0 Not rate of change 1 Rate x 0.1 2 Rate x 1 3 Rate x 10 4 Rate x 100 5 Rate x 1000 6

Seite 8 - 5. MECHANICAL ASSEMBLY

-14- FiLtrFiltering (continued) dEc.PtDecimal point selection(Scale and Offset selected)SCALEScale factor multiplier(not available for tC) OFFStOff

Seite 9 - 7. CONNECTORS

-15-DIGIT SELECT KEY VALUE SELECT KEY Select 0 through 9 for flash-ing digit. Decimal location isfixed by dEC.Pt selection.Select 0 through 9

Seite 10 - 8. FRONT PANEL SETUP KEYS

-16-DIGIT SELECT KEY VALUE SELECT KEY MENU KEY 0 0 AL1 Band deviation AL2 Band deviation 1 AL1 Hysteresis AL2 Band deviation 2 AL1 B

Seite 11 - 9. SETTING MENU LOCKOUTS

-17- 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 000Output filtering 000Baud rate 000000Di

Seite 12 - 10. SETUP MENU

ORDERING GUIDEL ...Laureate series meter withscrew terminal connectors.Display Color1 ... DPM with green LED2 ... DPM wi

Seite 13 - DC SIGNAL CONDITIONER

-18-0000Meter address for RS-232/RS-485 communication( digit display, address numberof meter)Note: Addresses 1 through 15are denoted by 1 through 9 an

Seite 14 - .XXX X.XXXX

-19-DIGIT SELECT KEY VALUE SELECT KEY MENU KEY 0 Enabled 1 Disabled 0 Enabled 1 Disabled 0 Enabled 1 Disabled 0 Enabled 1 Disabled

Seite 15

-20-11. DC VOLTS & AMPS11.1 RANGE JUMPER SELECTIONSFigure 11.1 DC Signal Conditioner11.2 MENU SELECTIONWhenever the scale factor is 1.0 and offset

Seite 16

-21-DIGIT SELECT KEY VALUE SELECT KEY Press the key todisplay SEtuP. (Basic setup)See Section 9, Page 10 fordetailed description of selec-tions

Seite 17

-22-12. PROCESS SIGNAL INPUTS12.2 MENU SELECTIONDisplay in engineering units is most easily programmed using the coordinates of 2 points. Thereare two

Seite 18

To set up the range using coordinates of 2 points, values for low signal input, low display, highsignal input and high display are entered. The follo

Seite 19

-24-DIGIT SELECT KEY VALUE SELECT KEY Press the key to displayHi rd (Desired meter readingat high signal input).Press to display valueand selec

Seite 20

-25-Press the key to displayInPut (Input type selection).Note: Selection of input type& range must match jumperselection in Section 13.1.Press

Seite 21

-26-14. Pt100 RTD'S14.1 RANGE JUMPER SELECTIONDIGIT SELECT KEY VALUE SELECT KEY Press to select short.Press the key to displayInPut (Inpu

Seite 22 - 11. DC VOLTS & AMPS

14.3 MENU SELECTIONSThe following example is setup for a 4-wire DIN RTD. When setting up the meter, it may benecessary to enable some of the menu ite

Seite 23

CONTENTS1. INTRODUCTION ... 22. RECEIVING AND UNPA

Seite 24 - 12. PROCESS SIGNAL INPUTS

-28-Press until rAtio (Ratio-metric operation) is dis-played.15 STRAIN GAUGES AND POTENTIOMETERSDIGIT SELECT KEY VALUE SELECT KEY Press the k

Seite 25 - 1 2 3 4 5

-29-Press the key to displaydEcPt (Decimal point).Press to display decimalpoint location.Use to set digit values andset to .00000 ( 0mV

Seite 26 - 13. THERMOCOUPLES

-30-16. AC (RMS) VOLTS & AMPSThis section provides basic setup instructions for true RMS voltage or current monitoring. An RMSsignal conditioner

Seite 27

-31-Press the key to displayInPut (Input type selection).Note: Selection of input type& range must match jumperselection in Section 16. 1.Pres

Seite 28 - 14. Pt100 RTD'S

-32-17. LOAD CELLS AND MICROVOLT INPUTSThis section provides setup instructions for use as a microvoltmeter or with load cells and straingauges. 10

Seite 29

-33-MENU KEY DIGIT SELECT KEY VALUE SELECT KEY Press to display decimalpoint location.Press the key todisplay dEcPt (Decimalpoint).Press

Seite 30

-34-18. DUAL ALARM OUTPUTS18.1 OPERATING MODE MENU SELECTIONWhen setting up the meter, it may be necessary to enable some of the menu items. See Sec

Seite 31

18.3 BAND DEVIATIONWhen deviation is selected from the setup menu, a value is entered for the amount of deviationrequired. This value represents the n

Seite 32 - 16. AC (RMS) VOLTS & AMPS

19. ANALOG OUTPUTThe analog output option provides a 0 to 20mA and a 0 to 10Vdc linear signal derived from thedisplayed reading. The low signal outpu

Seite 33

20. RS-232 AND RS-485 INTERFACE20. 1 OPERATING MODE MENU SELECTIONThe following menu items are accessible only with an RS-232 or RS-485 option insta

Seite 34

1. INTRODUCTIONThis series of panel instruments is a versatile, cost effective solution to a wide variety ofmonitoring and control applications. Thes

Seite 35

-38-15. RS-232 AND RS-485 INTERFACE15. 1 JUMPER SELECTIONSRS232 InterfaceJumper g - installed for normal operationJumper h - installed when used as

Seite 36 - 18. DUAL ALARM OUTPUTS

-39-21. 2 BCD OUTPUT LEVELSThe BCD option provides isolated, buffered, stored, 3-state parallel outputs that are selectablefor either 0 to 5V logic le

Seite 37

22. 5, 10 AND 24 VDC EXCITATION OUTPUTSacbdefhgFigure 22. 1 - Power Supply-40-22. 2 SELECTION OF OTHER JUMPERSJumper ' a ' - F

Seite 38 - 19. ANALOG OUTPUT

-41-23. DIGITAL INPUTSPress the key untilSEtup (Basic meter setup) isdisplayed.Press to display status.Press again to selectdigit. Selec

Seite 39

-42-24. CALIBRATIONAll ranges of the meter have been digitally calibrated at the factory prior to shipment. Thecalibration equipment is certified to

Seite 40

-43-ACCURACYDC AmperesVOLTAGERANGE200.00 mV2.0000 V20.000 V200.00 V660.0 V10 uV100 uV1 mV10 mV100 mV1 G1 G1 M1 M1 MRESOLUTIONINPUTOHMSERRORAT 25°CDC V

Seite 41 - 21. PARALLEL BCD OUTPUT

Span Tempco... 0.003% of reading/°CLoad Cell Meter only...

Seite 42

-45-IsolationCoil to Contacts ...Safety-rated to 250Vac, 4.2kVp per High Voltage TestBetween Open Contacts...

Seite 43 - .XXX X.XXXX

Rev P 11/06Copyright 1992-2006 Laurel Electronics, Inc.WARRANTYLaurel Electronics Inc. warrants its products against defects in materials or workmansh

Seite 44 - 25. SPECIFICATIONS

-3-2. RECEIVING AND UNPACKINGYour meter was carefully tested and inspected prior to shipment. Should the meter be damagedin shipment, notify the frei

Seite 45

4. CONNECTOR WIRING INFORMATION4.1 CONNECTOR LOCATIONThe connectors are the screw terminals that plug into the mating jack mounted on the printedcircu

Seite 46

-5-4.4 J4 - ANALOG OUTPUTLOAD CELL METER-10 V EXCITATION-SENSE-SIGNAL+SIGNAL+10 V EXCITATION+SENSE4.5 J 2 - DUAL SETPOINT CONTROLLER4.3 J5 - SIGNAL IN

Seite 47

-6-5.3 REASSEMBLING THE METERReverse the preceding procedures to reinstall the meter in the case. After the meteris in the case, insert the bottom ta

Seite 48 - Rev P 11/06

-7-FRONT VIEWMounting PawlTOP VIEWJ1 J2 J3 J4 J548mm(1.89in)96mm(3.78in)J1 J2 J3 J4 J5102mm(4.02in)5mm(0.1