KEYSTROKES FOR SETUP
If the MENU key does not work, see Section 9 “Enabling & Locking Out Menu Items.”
Press
Menu
Press Digit
Select Key
Press Value Select
Key
0000
Setpoint 1 compared to:
1. Filtered item 2 Item #2
1 Item #1 3 Item #3
0000
Setpoint 2 compared to:
1. Filtered item 2 Item #2
1 Item #1 3 Item #3
0000
Setpoint 3 compared to:
1. Filtered item 2 Item #2
1 Item #1 3 Item #3
SourcE
Source to com-
pare to setpoint
0000
Setpoint 4 compared to:
1. Filtered item 2 Item #2
1 Item #1 3 Item #3
00000
Relay alarm state when
alarm is active
0 Relay 1 active on Relay 2 active on
1 Relay 1 active off Relay 2 active on
2 Relay 1 active on Relay 2 active off
3 Relay 1 active off Relay 2 active off
00000
Alarm latching or non-
latching (auto reset)
(see Glossary)
0 AL1 non-latching AL2 non-latching
1 AL1 latching AL2 non-latching
2 AL1 non-latching AL2 latching
3 AL1 latching AL2 latching
00000
Alarm operates at and
above setpoint (active
high) or at and below
setpoint (active low).
(see Glossary)
0 AL1 active high AL2 active high
1 AL1 active low AL2 active high
2 AL1 disabled AL2 active high
3 AL1 active high AL2 active low
4 AL1 active low AL2 active low
5 AL1 disabled AL2active low
6 AL1 active high AL2 disabled
7 AL1 active low AL2 disabled
8 AL1 disabled AL2 disabled
00000
Hysteresis mode or band
deviation mode
(see Glossary)
0 AL1 band deviation AL2 band deviation
1 AL1 hysteresis AL2 band deviation
2 AL1 band deviation AL2 hysteresis
3 AL1 hysteresis AL2 hysteresis
4 No deviation or hysteresis on menu
5 AL1 span hysteresis AL2 band deviation
6 AL1 span hysteresis AL2 hysteresis
7 AL1 span hysteresis AL2 span hysteresis
AL SEt
Alarm Setup
for relays 1 & 2
if detected.
Press until
ALSEt is
displayed.
00000
Number of consecutive
readings in alarm zone to
cause an alarm
0 After 1 reading 4 After 16 readings
1 After 2 readings 5 After 32 readings
2 After 4 readings 6 After 64 readings
3 After 8 readings 7 After 128 readings