Laurel-electronics Modbus Protocol For Series 2 Laureate Digital Pane Bedienungsanleitung Seite 8

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 7
- 8 -
E1
E4
E6
E3
E2
a
b
c ab
a
b
cd
a
b
c
d
Serial Signal Duplex Jumpers Termination Resistor*
Full None
E6 a = Transmit
E6 c = Receive
RS485
Half E6 b + d** E6 c
RS232 Full None None
Serial Signal Duplex Jumpers Termination Resistor*
Full None
E6 a = Transmit
E6 c = Receive
RS485
Half E6 b + d** E6 c
RS232 Full None None
* The termination resistor jumper settings should only be selected if the transmitter is the last
device on an RS485 line longer than 200 feet (60 m).
** Attempting to draw more than the rated current will shut down the output.
To reset communications to 9600 baud, command mode, Custom ASCII protocol, and Address 1,
place a jumper at E1 and power up the transmitter.
Analog Output Jumpers
Current E2 a + d
Voltage E2 b + c
Excitation Output* Jumpers
5V, 100 mA E3 a + c; E4 a
10V, 120 mA E3 a + c; E4 b
24V, 50 mA E3 b, E4 none
* The termination resistor jumper
settings should only be selected
if the transmitter is the last device
on an RS485 line longer than 200
feet (60 m).
** Or jumper external BTX to BRX
and ATX to ARX (same effect as
internal jumpers).
Seitenansicht 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 31 32

Kommentare zu diesen Handbüchern

Keine Kommentare