ALARMS Key. Pressing ALARMS once displays the setpoint for Alarm 1. Pressing it
again displays the setpoint for Alarm 2. Pressing it again returns to the present value.
After 30 seconds, the meter automatically returns to the present value. Timing is
automatically reset whenever the ALARMS key is pressed.
KEYS IN MENU MODE
Right Arrow Key (MENU). Pressing steps the meter through all menu items that
have been enabled and then back to the Run Mode. If a change has been made to a
menu item, that change is saved to non-volatile memory when the key is pressed
next, and _StoreE is displayed briefly.
Right Triangle Key (Digit Select).
Pressing from most menus selections sequentially selects digit positions 1 - 6, as
indicated by a flashing digit: 000000, 000000, 000000, 000000, 000000, 000000.
Up Triangle Key (Value Select). Pressing for a flashing digit position or decimal
point position will increment that item. Pressing the MENU key will save any changes.
Left Arrow Key (Reverse Menu). Pressing has the same effect as the MENU key,
except that menu items are brought up in reverse order.